Products » CAMTOP BOP Testing Unit | API 16D | 5K–20K PSI | Pneumatic / Electric

CAMTOP BOP Testing Unit | API 16D | 5K–20K PSI | Pneumatic / Electric

Out of stock

CAMTOP API 16D BOP Testing Unit — pneumatic, electric, and electro-pneumatic pressure test units from 5,000 to 20,000 PSI. Skid-mounted, portable, and vehicle-mounted configurations with chart pressure recorder and digital data logger for BOP stack, choke & kill line, and Christmas tree pressure testing.

This product is currently out of stock and unavailable.

SKU: CT-BTU-001 Category:

Description

API 16D BOP Testing Unit — Skid-Mounted, Portable & Electro-Pneumatic


The CAMTOP BOP Testing Unit is a high-pressure hydrostatic pressure test pump purpose-built for field and shop testing of blowout preventer (BOP) stacks, choke & kill lines, wellhead Christmas trees, and other pressure-containing equipment. The unit is fully compliant with API 16D design and performance requirements, and is offered in pneumatic, electric, and electro-pneumatic configurations to suit any wellsite or shop environment.

Standard working pressure ranges from 5,000 to 20,000 PSI, with explosion-pressure ratings up to 225 MPa. Every unit is supplied with an automatic chart pressure recorder (per API 16D), high-pressure hose assemblies, and the instrumentation required for one-person operation. Units are available skid-mounted, portable, vehicle-mounted, or shop-configured.

Product Image


CAMTOP BOP Testing Unit — API 16D skid-mounted pressure test unit, dual-pump configuration (pneumatic / electric / electro-pneumatic), chart recorder, 5K–20K PSI working pressure range for BOP stack testing, choke and kill lines, and wellhead Christmas tree pressure testing

Available Configurations


CAMTOP Pneumatic BOP Testing Unit — API 16D high-pressure air-driven test pump, FRL air regulator, large dial gauge, 10,000 PSI working pressure, for BOP stack pressure testing and wellhead equipment hydrostatic testing

Pneumatic BOP Testing Unit — air-driven, FRL regulator, large dial gauge, ideal for hazardous-area wellsite deployment.

CAMTOP Portable BOP Testing Unit — API 16D mobile pressure test pump with twin pneumatic pumps, circular chart pressure recorder and digital data logger, wheeled frame for field deployment, wellhead BOP stack pressure testing

Portable BOP Testing Unit — twin pneumatic pumps, circular chart recorder + digital data logger, wheeled frame for one-person field deployment.

Key Features


  • API 16D Compliant — Chart pressure recorder, control valve, and high-pressure hose assemblies all conform to API 16D specification
  • Three Drive Options — Pneumatic, electric, or combined electro-pneumatic; suitable for hazardous-area or grid-powered locations
  • Wide Pressure Range — Working pressure from 5,000 to 20,000 PSI (35 to 140 MPa); explosion-pressure ratings up to 225 MPa
  • Local & Remote Control — Operator can start / stop / vent from the unit or from a remote control station
  • Continuous Monitoring — Chart recorder prints and tracks the test pressure in real time; digital data logger optional
  • Compact & Lightweight — Small footprint and low weight for transport on pick-up trucks, skid trailers, or offshore supply boats
  • Low Noise — Sound-insulated enclosures and tuned pneumatic circuits for wellsite-friendly operation
  • Easy Maintenance — Modular plumbing with quick-disconnect fittings; spare seal kits and pump heads available ex-stock
  • Custom Skid Packages — Enclosed shelters, offshore DNV 2.7-1 lifting frames, and arctic-rated versions available on request
  • Certifications — Designed and manufactured per API, ISO, GOST, CE, and customer-specific requirements

Technical Specifications


Parameter Specification
Product Type API 16D BOP Testing Unit (Pressure Test Pump)
Design Standard API 16D, API 16A, ISO 9001, GOST, CE
Drive Types Pneumatic / Electric / Electro-Pneumatic
Working Pressure Range 5,000 – 20,000 PSI (35 – 140 MPa)
Maximum Explosion / Burst Pressure Up to 225 MPa
Pneumatic Pump Ratios 1:30 / 1:60 / 1:100 / 1:200 / 1:225
Air Supply Pressure (Pneumatic) 0.7 MPa (100 psi) clean, dry air
Air Consumption (Pneumatic) ≈ 1.5 m³/min
Pneumatic Pump Stroke Volume 14 – 180 ml/stroke (ratio dependent)
Electric Pump Power 30 kW (35 MPa) / 55 kW (105 MPa)
Electric Pump Displacement 2,300 L/h (35 MPa) / 1,560 L/h (105 MPa)
Supply Voltage (Electric) 380 VAC, 3-phase, 4-wire (customizable)
Ambient Temperature −10 °C to +50 °C
Oil Tank Volume 45 – 100 L (model dependent)
High-Pressure Hose Working pressure 70 / 105 MPa; ID 12.7 mm; NPT1 / M24×1.5 outlet
Pressure Recorder Stand-mounted circular chart recorder + optional digital data logger
Configurations Skid-Mounted / Portable / Vehicle-Mounted / Shop
Control Local panel + remote start / stop / vent

Pneumatic BOP Testing Unit — Model Selection


Model Pump Ratio Working Pressure (MPa) Input Air Pressure (MPa) Oil Tank (L) Burst Pressure (MPa)
CBT-QT21 1:30 21 0.7 45
CBT-QT35 1:100 35 0.5 – 0.8 100
CBT-QT70 1:100 70 0.7 100 84
CBT-QT140 1:100 140 0.7 100 168
CBT-QT200 1:100 200 0.9 100 225
CBT-QT140A 2:100 140 0.7 100 168
CBT-QT140B 1:100 140 0.7 100 168
CBT-QT140C 1:100 140 0.7 100 168

Electric & Electro-Pneumatic Models


Model Drive Type Working Pressure (MPa) Power / Air Displacement / Stroke Outlet
CBT-DT35-J Electric 35 30 kW / 380 VAC 2,300 L/h NPT1 Male
CBT-DT105-J Electric 105 55 kW / 380 VAC 1,560 L/h NPT1/2 Female
CBT-DQT70-J Electro-Pneumatic 70 380 VAC + 0.7 MPa air / 1.5 m³/min 50 L/min
CBT-DQT105-J Electro-Pneumatic 105 380 VAC + 0.7 MPa air / 1.5 m³/min 21 L/min

Operating Principle


The CAMTOP BOP Testing Unit uses a pneumatically- or electrically-driven high-pressure pump to deliver controlled hydraulic pressure to the BOP stack, choke / kill lines, or Christmas tree under test. The operator sets the target test pressure on the panel; the system pressurizes slowly and holds the pressure for the duration of the test while the API 16D chart recorder plots a continuous pressure-vs-time trace.

Should the pressure drop below the test threshold, the operator can re-pressurize the system from the local panel or from a remote station. A manual vent valve provides controlled depressurization at the end of each test.

Typical Applications


  • On-site hydrostatic pressure testing of BOP stacks (annular, ram, and choke & kill BOPs)
  • Pressure testing of wellhead Christmas trees and production assemblies
  • Choke & kill line pressure verification
  • Surface equipment integrity verification after refurbishment
  • Shop testing of pressure-containing components prior to dispatch
  • Onshore and offshore drilling rigs, workover spreads, and well-test spreads
  • Compliance testing per API 16D, API 16A, and operator-specific well control procedures

Why Choose CAMTOP


  • API 16D Compliance — Every BOP Testing Unit is supplied with full API 16D documentation, FAT records, and MTC
  • Three Drive Options — Pneumatic, electric, or combined electro-pneumatic from a single supplier
  • Standard Models in Stock — Common 5K / 10K / 15K / 20K PSI units available with short lead times
  • Custom Skid Packages — Vehicle-mounted, offshore-rated, DNV 2.7-1 lifting, enclosed shelter, arctic-grade versions
  • Field-Proven Reliability — Hundreds of units operating in the Middle East, North Sea, Asia-Pacific, and the Americas
  • Engineering Support — Our team designs the test circuit, hose runs, and instrumentation layout for your specific rig
  • Spare Parts & Service — Pump heads, seal kits, gauges, and recorders available ex-stock for fast turnaround

Ordering Information


To request a quotation, please provide the following information:

  • Maximum working pressure required (PSI or MPa)
  • Drive type: Pneumatic / Electric / Electro-Pneumatic
  • Configuration: Skid-mounted, portable, vehicle-mounted, or shop
  • Number of test circuits / outlets and hose length required
  • Chart recorder type (circular, digital, or both) and certifications required
  • Operating environment (onshore / offshore, ambient temperature, hazardous area)
  • Project location and applicable standards (API 16D, ISO, CE, GOST, etc.)

Contact CAMTOP


For technical specifications, datasheets, and quotations, please contact our oilfield equipment sales team:

CAMTOP delivers API 16D-compliant BOP Testing Units with fast lead times, full documentation, and competitive pricing. Contact us today to discuss your next well control test equipment requirement.

Reviews

There are no reviews yet.

Be the first to review “CAMTOP BOP Testing Unit | API 16D | 5K–20K PSI | Pneumatic / Electric”

Your email address will not be published. Required fields are marked *

Contact Info

No. 432, Fute North Road, Pudong District, Shanghai, Chian

Phone: +86.21.58432768

Mobile: Whatsapp: 86-18621723891

Fax: +86.21.58432768

Web: www.camtop-oilfieldtools.com

Recent Posts